CSI Division 07 Fireproofing

Fireproofing Estimating Services & Takeoffs

Accurate CSI Division 07 fireproofing cost estimates, spray-applied fire-resistive materials (SFRM), thin-film intumescent coatings, and through-penetration firestop takeoffs across the USA.

24–48 Hr Turnaround
Commercial & Residential
All 50 U.S. States
Bid-Ready Deliverables
Sample Fireproofing Estimating Services Takeoff Summary
Illustrative Plan Sample

Representative Quantification & BOQ Deliverable

Work Item / SpecificationQuantityUnit
Standard Density Cementitious SFRM (1-1/8" Thk @ 2-Hr)
48,500BF
15 PCF Cementitious SFRM on Columns (1-3/8" Thk @ 2-Hr)
24,200BF
Fluted Metal Floor Deck Spray (3/4" Thk @ 2-Hr)
32,000SF
Monokote MK-6 / Cafco 300 Bags (50 lb Bags)
1,850BAGS
Delivered in Excel (.XLSX) & Bluebeam Marked PDFsCSI Division 07 81 00
11+ Years
Industry Experience

Specialized construction takeoffs

500+
Completed Projects

Across all major trades & scopes

24–48 Hrs
Typical Turnaround

Standard scopes; fast bid response

CSI Division 07 Fireproofing
CSI MasterFormat

Plan-based quantity takeoffs

Industry Definition & Core Concept

What Is Fireproofing Estimating?

Fireproofing estimating is the technical calculation of material board feet, dry film thickness (DFT), wet film thickness (WFT), bags of cementitious/mineral fiber spray-applied fire-resistive materials (SFRM), gallons of intumescent mastic coatings, and through-penetration firestopping based on structural steel framing plans, hourly fire ratings (1-Hr, 2-Hr, 3-Hr), and UL design listings (UL X700/X800 series).

Fireproofing costs depend directly on the W/D (weight-to-perimeter) or A/P ratios of steel members. Lightweight steel beams require significantly thicker fireproofing to achieve a 2-hour rating than heavy steel columns. Estimators must also calculate overspray waste factors, masking/taping protection, and temperature-controlled curing requirements.

At F&K Estimatings, our fireproofing estimators map every structural beam, column, truss, and metal deck flute to exact UL design assemblies, calculating board foot yields, intumescent mil thicknesses, and specialized spray rig applicator labor hours.

01

Life Safety & UL Audit

UL design listings, hourly ratings (1/2/3-Hr), steel member sizes

02

W/D Ratio & Thickness Calculation

Weight-to-heated-perimeter ratio conversion to exact thickness

03

SFRM & Intumescent Takeoff

Board footage (BF), bag counts, gallons & spray flutes

04

Firestopping & Joint Seals

Head-of-wall joints, pipe/duct penetrations & putty pads

05

Overspray & Masking Allocation

Polyethylene floor/wall masking, cleanup & equipment rigs

06

Senior Estimator QA

Special inspections (ASTM E605/E736) & bid package

Complete Scope Transparency

What Does a Fireproofing Estimating Services Include?

Every estimate prepared by F&K Estimatings delivers an exhaustive line-item breakdown formatted for material suppliers, specialty subcontractors, and general contractor bid reviews.

Estimate ComponentIncluded Scope & Line ItemsUnit of Measure
Standard Density Cementitious SFRM
15 lb/cu ft standard density spray-applied fireproofing (Monokote MK-6 / Cafco 300) for concealed structural beams/columns.Board Feet (BF) / Bags
Medium & High-Density SFRM
22 lb & 40 lb/cu ft medium/high density fireproofing (Monokote Type Z-106 / Cafco Fendolite) for mechanical rooms & parking garages.Board Feet (BF) / Bags
Thin-Film Intumescent Coatings
Water-based and solvent-based thin-film intumescent coatings (Sherwin-Williams FireTex, Carboline Thermo-Sorb, Albi Clad).Dry Mils / Gallons
Corrugated Metal Deck Fireproofing
Spray fireproofing applied to fluted composite metal floor and roof decking, including valley fills and flat deck runs.Square Feet (SF) / BF
Head-of-Wall Firestop Joints
Fire-rated elastomeric spray sealants, mineral wool safing, and intumescent joint strips at deck-to-wall intersections.Linear Feet (LF) / Gallons
Through-Penetration Firestopping
Intumescent firestop sealants, collar wraps for plastic pipes, firestop pillows, composite sheets, and outlet putty pads.Count (EA) / Tubes
Rigid Board Fireproofing
Mineral wool boards, calcium silicate boards, and composite fire barrier boards for structural columns and kitchen grease ducts.Square Feet (SF) / Boards
Polyethylene Masking & Surface Prep
6 mil poly containment sheeting, floor protection, tape, structural steel primer compatibility reviews.Square Feet (SF) / Rolls
Fireproofing Labor & Spray Rigs
Certified spray pump operator and nozzleman crew hours, scaffold/scissor lift rentals, cleanup, special inspection prep.Crew Days / Pump Rental
Bid-Ready Fireproofing BOQ
Itemized Excel workbook with UL designs, thickness schedules, bag counts, intumescent gallons, and marked PDF drawings.Complete Bid Package
Comprehensive Trade Capabilities

Fireproofing Estimating Services Scope & Material Quantities

Select a category below to explore our specific measurement parameters and deliverable formats.

CSI Division 07 Fireproofing Scope Area

Division 07 Spray-Applied Fire-Resistive Materials

Complete takeoff of concealed and exposed cementitious fireproofing on wide flange beams, columns, and decks.

Standard Density Cementitious SFRM (15 PCF)
Medium & High-Density SFRM (22 & 40 PCF)
Fluted Metal Deck Spray & Valley Fills
W-Shape Primary Beams & Transfer Girders
Structural Steel Columns & Tube Bracing
Bonding Agents (Latex Primers) over Steel

Deliverable Format

Board Footage (BF = 1 SF @ 1" thickness), bag counts (50 lb bags), and pump crew hours.

Planswift / Bluebeam Marked100% Itemized
CSI MasterFormat Standards

CSI MasterFormat Division 07 Fireproofing Standards

Our fireproofing takeoffs are structured under CSI MasterFormat Division 07 and reference Underwriters Laboratories (UL) Fire Resistance Directories.

Every steel member is mapped to its exact UL Design number and hourly rating.

07 81 00

Applied Fireproofing

Spray-applied cementitious and mineral fiber fire-resistive materials.

07 81 23

Intumescent Fireproofing

Thin-film and thick-film intumescent coatings for exposed steel.

07 82 00

Board Fireproofing

Rigid calcium silicate and mineral wool board enclosures.

07 84 00

Firestopping

Through-penetration firestops, firestop joints, and perimeter fire barriers.

07 84 43

Joint Firestopping

Head-of-wall joint sealants, deflection joints, and expansion seals.

07 84 53

Building Inclosure Firestopping

Edge-of-slab perimeter curtain wall fire containment.

Fireproofing Detailing

UL Design Assembly & W/D Ratio Modeling

Fireproofing estimating requires calculating the W/D ratio (weight per foot divided by heated perimeter) for every structural steel beam and column, cross-referencing UL Design tables to determine the exact required fireproofing thickness.

W/D ratio calculated for every beam, column, channel, and HSS tube member
UL Design number cross-referencing (e.g., UL N708, X771, N823, D916)
Board Footage conversion (1 Board Foot = 144 cubic inches of material)
Intumescent dry mil thickness curves tailored to specified hourly fire ratings
Overspray waste allowances (typically 15% to 25% based on beam spacing)
Color-coded framing plans detailing fireproofing thicknesses across all floors

Need a Specialized Fireproofing Estimating Services?

Send your drawing sheets for a dedicated takeoff schedule.

Upload Structural & Life Safety Plans

Standard SFRM Coverage Factors

Reference metrics applied by our fireproofing estimators:

1 Board Foot (BF)1 Sq Ft @ 1" ThkStandard volume unit
Monokote MK-6 Bag42 - 45 BF / BagStandard yield
Cafco 300 Bag40 - 44 BF / BagStandard yield
Intumescent 100% Solid1,604 Mil-SF / GalTheoretical coverage
Standard Spray Waste15% - 25%Overspray & flutes
Intumescent Spray Waste10% - 15%Airless spray loss
Key Estimating Distinction

Fireproofing Takeoff vs. Complete Fireproofing Estimating

Understanding whether your team needs raw quantity measurements or a fully priced bid estimate helps you order the exact service you require.

Direct Summary: A fireproofing quantity takeoff measures total Board Footage (BF), SFRM bag counts, intumescent paint gallons, and firestop joint linear footage. A complete estimate adds certified spray rig operator labor hours, masking/containment poly, scissor lift rentals, equipment fuel, cleanup, and contractor profit margins.
Material Quantity Takeoff (QTO)
Quantities Only
Scope: Board Feet (BF), Bag counts, Paint gallons, Joint LF, and Firestop counts.
Best For: Fireproofing contractors and material distributors with internal piece rates and spray rig setups.
Deliverables: Itemized Excel Bill of Materials (BOM) & high-resolution Bluebeam marked drawings.
Turnaround: 24–36 Hours.
Complete Priced Bid Estimate
Full Cost & Bid Ready
Scope: Material Takeoffs + Certified Spray Crew Labor + Masking/Protection + Rigs + Margin.
Best For: Fireproofing Subcontractors bidding GC tenders, General Contractors checking bids, and Developers.
Deliverables: Complete priced Excel proposal, labor crew breakdown, and marked drawings.
Turnaround: 24–48 Hours.
Standard Engineering Workflow

F&K Fireproofing Estimating Services Quantification & Review Workflow

Our systematic 7-step engineering process eliminates missing elements, prevents duplicate counts, and delivers defensible estimates.

01

Life Safety & Structural Drawing Audit

We review Code Summaries, UL listings, fire rating plans (1/2/3-Hr), structural framing plans, and Division 07 specs.

02

Member W/D Ratio & Thickness Determination

We calculate the W/D ratio for every steel member and determine exact required thickness from UL charts.

03

Board Footage (BF) & Bag Count Takeoff

We measure linear member lengths and deck areas, multiplying surface area by thickness to compute Board Feet and bag yields.

04

Intumescent Coating Mil Thickness Takeoff

We calculate surface areas for exposed architectural steel, mapping specified hourly ratings to required dry mil thicknesses.

05

Firestop Joints & Penetrations Takeoff

We measure head-of-wall joints, edge-of-slab fire safing, and count MEP pipe/conduit penetration sleeves.

06

Masking, Labor Crew & Spray Rig Allocation

We calculate polyethylene masking square footage, spray rig pump rental durations, and nozzleman crew days.

07

Senior Fireproofing Estimator QA

A Senior Estimator conducts a peer review to verify UL assembly compliance, thickness calculations, and addenda.

Sector Expertise

Fireproofing Estimating Services for Every Construction Sector

From commercial tenant fit-outs to heavy industrial complexes, we adapt our takeoff methodology to project specifications.

Commercial Steel Office Towers

Multi-story wide flange steel framing, composite fluted floor decks, 2-hour columns, and head-of-wall joint seals.

2-Hr Column SFRM
1-Hr Floor Beam SFRM
Fluted Deck Spray
Head-of-Wall Spray
Atriums & Exposed Architectural Steel

Decorative trusses, exposed lobby columns, and skylight framing requiring thin-film intumescent coatings.

Intumescent Mastic
Smooth Finish Paint
Mil Gauge Control
Primer Compatibility
Hospitals & Healthcare Facilities

High-density moisture-resistant SFRM in mechanical rooms, cleanroom containment, and 2-hour shaftwalls.

High-Density SFRM
Shaftwall Firestops
Cleanroom Containment
Rigid Safing
Parking Structures & Garages

Medium-density moisture-resistant cementitious fireproofing on exposed structural steel transfer girders.

Medium-Density SFRM
Bonding Primers
Vibration Resistance
Impact Resistance
Industrial Plants & Refineries

High-density cementitious fireproofing and hydrocarbon intumescent coatings for blast/fire resistance.

Hydrocarbon Fireproofing
Refinery Columns
Blast Resistance
Industrial Mesh
Restaurants & Commercial Kitchens

2-hour flexible ceramic grease duct thermal insulation wraps and penetration firestop collars.

Grease Duct Wraps
Ceramic Fiber Blankets
Firestop Collars
Access Door Flashing

Fireproofing Estimating Services Elements We Quantify

Standard Density Cementitious SFRM (15 PCF)
Medium & High-Density Cementitious SFRM
Water-Based Thin-Film Intumescent Coatings
Solvent-Based / Epoxy Intumescent Mastic
Fluted Metal Floor & Roof Deck Fireproofing
Wide Flange Beams & Primary Transfer Girders
HSS & Pipe Structural Steel Columns
Head-of-Wall Firestop Elastomeric Spray
Mineral Wool Edge-of-Slab Fire Safing
Intumescent Pipe Collars & Firestop Sealants
Calcium Silicate Rigid Board Fireproofing
Grease Duct 2-Hour Ceramic Blanket Wraps
Latex & Epoxy Substrate Bonding Primers
6 mil Polyethylene Masking & Floor Covering
Special Inspection Testing Prep (ASTM E605)
Plaster Spray Rig Pump & Compressor Rentals
Pricing Methodology

How Fireproofing Estimating Services Costs Are Calculated

Material and labor costs fluctuate drastically by project geography, supplier logistics, trade union jurisdictions, and site conditions. We do not use flat national averages.

Our cost database integrates regional material supplier pricing, union prevailing wage scales, open-shop labor rates, and local equipment rental benchmarks across all 50 U.S. states.

Steel W/D Ratios & Thickness Requirements

Lightweight steel members with low W/D ratios require thicker fireproofing layers, increasing material bag consumption.

Intumescent vs Cementitious SFRM Material Costs

Intumescent coatings cost 4x to 8x more per square foot than standard cementitious spray but provide smooth architectural finishes.

Jobsite Masking & Containment Requirements

Protecting existing finishes, glass curtain walls, and mechanical ductwork in occupied spaces adds substantial masking labor.

High-Bay Scaffolding & Boom Lift Access

Spraying steel above 14 feet requires electric scissor lifts or staging platforms, reducing daily square-foot production.

Cold Weather Heating & Humidity Control

Cementitious and intumescent materials require minimum 40°F–50°F substrate temperatures for proper adhesion and curing.

Benchmark Project Models

Representative Fireproofing Estimating Services Scenarios

Review illustrative project models demonstrating how CSI Division 07 Fireproofing quantities are extracted, itemized, and structured under standard contractor bidding conditions.

Dallas, TX Market Model
Illustrative Scenario
Commercial 6-Story Steel Framed Building
Scope: Full fireproofing: 2-hr columns, 1.5-hr beams, fluted deck spray, head-of-wall joint spray, 6 mil poly masking.
128,000 BF Cementitious SFRM • 2,900 Bags MK-6 • 4,200 LF Head-of-Wall • Poly Containment
Priced Division 07 fireproofing estimate delivered in 48 hours for general contractor tender.
Columbus, OH Market Model
Illustrative Scenario
Airport Terminal Architectural Atrium Steel
Scope: Intumescent coating: 2-hour thin-film water-based intumescent on exposed tubular trusses and feature columns.
18,500 SF Exposed Steel • 120 Mils DFT • 1,420 Gallons Intumescent • Smooth Topcoat
Granular material takeoff used by specialty painting/fireproofing contractor to win bid.
Orlando, FL Market Model
Illustrative Scenario
Hospital Central Utility Plant & Grease Ducts
Scope: Specialty fireproofing: High-density 40 PCF SFRM in boiler room, 2-hour ceramic grease duct wrap, penetrations.
14,500 BF High-Density SFRM • 2,400 SF Grease Duct Wrap • 180 Firestop Collars
Subcontractor bid spreadsheets with material yield and spray crew labor hours.

Senior Fireproofing Estimating Services Oversight

Every estimate is produced and audited by experienced estimators with construction management and trade-specific takeoff backgrounds, adhering strictly to industry standards.

CSI Division 07 Fireproofing Specification-Informed Takeoffs
Industry-Standard Estimating Principles
Bluebeam & Planswift Digital Workflows
Trust & Technical Authority

Why General Contractors & Trade Subcontractors Trust F&K

When bidding tight commercial deadlines, subcontractors cannot afford incomplete takeoffs or guesswork. F&K provides the technical depth of an in-house senior estimating team at a fraction of the overhead.

Plan-Based Accuracy

Every item is mapped directly to marked drawing sheets with zero unverified fluff.

Addenda Protection

Instant delta revisions when engineers issue revised plan sets prior to bid closing.

Ready for Subcontractor Bids

Customizable Excel files with formulas intact so you can adjust your own margins instantly.

National Geo Pricing

Location-specific pricing calibrated for urban, suburban, and rural jobsites across all 50 states.

Answer Hub & Knowledge Base

Fireproofing Estimating Services FAQs

Detailed technical and commercial answers to help you navigate fireproofing estimating services, material scheduling, and bid preparation.

Start Your Estimate Today

Send Your Plans & Get a Fireproofing Estimating Services Quote

Upload your architectural, structural, or engineering drawings. Our estimators will review your plan set and deliver a free quote within 1–2 hours.

Direct Estimator Submission

Upload Plans for a Fireproofing Estimating Services

Get a line-item CSI Division 07 Fireproofing quantity takeoff & pricing report delivered in 24–48 hours.

24–48 Hr Standard Turnaround CSI Division 07 Fireproofing Compliant Excel & Marked PDF Deliverables
Prefer direct email? Send files to info@fandkestimatings.comImmediate phone consultation: (317) 751-5969
LIMITED TIME OFFER

45%

OFF

Your First choice
Construction Estimation

9DAYS
05HRS
05MINS

Estimate Support

Get 45% OFF
on your first Estimate!